Control-IQ pancreas system maintains blood sugar levels round the clock in T1 diabetes
A new artificial pancreas system, called Control-IQ is more effective than existing treatments at controlling blood sugar levels in people with type 1 diabetes. The researchers found that the new artificial pancreas system called the Control-IQ system works by adjusting insulin delivery automatically using algorithms. The research has been published in the New England Journal of Medicine.
The study showed that the system improved participants' blood sugar control throughout the day and overnight in people with type 1 diabetes. The latter is a common but serious challenge for children and adults with type 1 diabetes since blood sugar can drop to dangerously low levels when a person is asleep.
"This artificial pancreas system has several unique features that improve glucose control beyond what is achievable using traditional methods," said Kovatchev co-lead author of the study. "In particular, there is a special safety module dedicated to the prevention of hypoglycemia, and there is gradually intensified control overnight to achieve near-normal blood sugar levels every morning."
The artificial pancreas, also known as closed-loop control, is an "all-in-one" diabetes management system that tracks blood sugar levels using a continuous glucose monitor (CGM) and automatically delivers the hormone insulin when needed using an insulin pump. The system replaces reliance on testing by fingerstick or CGM with separate delivery of insulin by multiple daily injections or a pump.
The International Diabetes Closed-Loop (iDCL) Study involves five separate artificial pancreas clinical protocols implemented by 10 research centres, including CU Anschutz. This six-month study was the third phase in the series of trials. It was conducted with participants living their usual day-to-day lives, so the researchers could best understand how the system works in typical daily routines.
"Testing the safety and effectiveness of new technologies in real-world settings is critical to prove the usability of these systems by people with diabetes to achieve a better daily control of their blood glucose levels," said Guillermo Arreaza-Rubín, M.D., director of NIDDK's Diabetes Technology Program and project scientist for the study.
This iDCL protocol enrolled 168 participants age 14 or older with type 1 diabetes. They were randomly assigned to use either the artificial pancreas system called Control-IQ or sensor-augmented pump (SAP) therapy with a CGM and insulin pump that did not automatically adjust insulin throughout the day. Participants had contact with study staff every two to four weeks to download and review device data. No remote monitoring of the systems was done, so that the study would reflect real-world use.
The results showed that participants using the Control-IQ system achieved a longer time in the target glucose level range by 2.6 hours on average per day compared to their time in target prior to using the system. The average percentage of time in range went from 61% of time spent in range prior to the intervention, up to 71% of time in range after using the artificial pancreas system
High adherence to device use in both groups and 100% participant retention were important strengths of the study. During the study, no severe hypoglycemia events occurred in either group. Diabetic ketoacidosis occurred in one participant in the artificial pancreas group due to a problem with equipment that delivers insulin from the pump.
The Control-IQ technology was derived from a system originally developed at the University of Virginia, Charlottesville, (UVA) by a team led by Boris Kovatchev, Ph.D., director of the UVA Center for Diabetes Technology with funding support from NIDDK. In this system, the insulin pump is programmed with advanced control algorithms based on a mathematical model that uses the person's glucose monitoring information to automatically adjust the insulin dose. Tandem Diabetes Care has submitted the results to the U.S. Food and Drug Administration for approval to market the Control-IQ system.
Kovatchev was co-lead author of the study with colleagues Sue A. Brown, M.D., of UVA and Roy Beck, M.D., Ph.D., from the Jaeb Center for Health Research, Tampa, Florida, which was the coordinating center for the study.
"This study demonstrated that in participants with type 1 diabetes, use of the Control IQ system led to improved glucose control during both the day and night for a wide range of ages including adolescents to older adults," said co-author R. Paul Wadwa, MD, associate professor of pediatrics at the Barbara Davis Center for Childhood Diabetes at CU Anschutz. "We greatly appreciate the involvement of participants and hard work of study teams to complete this important study. We are hopeful that the system studied in this trial will potentially offer a valued treatment option to benefit people with type 1 diabetes."
For more details click on the link: DOI: 10.1056/NEJMoa1907863
Disclaimer: This site is primarily intended for healthcare professionals. Any content/information on this website does not replace the advice of medical and/or health professionals and should not be construed as medical/diagnostic advice/endorsement or prescription. Use of this site is subject to our terms of use, privacy policy, advertisement policy. © 2020 Minerva Medical Treatment Pvt Ltd