Robot assisted retinal screening in diabetes soon

Published On 2019-11-24 13:45 GMT   |   Update On 2021-08-11 10:23 GMT

Diabetes often described as a lifestyle has become increasingly common. The soaring number of patients suffering from this chronic metabolic disorder has led to evolvement of new diagnostic procedures. Digital retinal screening a successful and promising technique is going to play an important role in the diagnosis of other diseases in the future.


The digital revolution in ophthalmology has now become a clinical reality and a number of hospitals are now using automatic digital retinal screening, without assistance from an ophthalmologist, to detect diabetic retinal disease. There is now a cost-effective and efficient AI solution to ensure early detection as part of routine general medical care which is a robot-assisted diagnosis.


"The robot makes the diagnosis all on its own," said Ursula Schmidt-Erfurth, head of the Department of Ophthalmology and Optometrics of the Medical University of Vienna, speaking today (Tuesday) at a press conference in Vienna in advance of the Advanced Retinal Therapy Conference "ART 2019" to be held in Vienna on 23 November, which will specifically focus on the use of Artificial Intelligence (AI) in ophthalmology.








There is now a cost-effective and efficient AI solution to ensure early detection as part of routine general medical care: A robotic camera, no bigger than a coffee machine and costing around €20,000, is being used under the direction of MedUni Vienna's eye hospital in the three diabetology departments of MedUni Vienna, the Rudolph Foundation and in Kaiser-Franz-Josef Hospital. It is able to diagnose within a matter of minutes whether diabetic patients already have retinal damage requiring treatment. "The presence of a doctor is not necessary for this screening. The patient sits in front of the camera and the results come out of the printer five minutes later," said Schmidt-Erfurth, who heads up the Christian Doppler Laboratory for Artificial Intelligence in Ophthalmology. "The robot clearly states whether there is currently no damage, moderate damage or damage that requires urgent treatment and routes the patient directly to an ophthalmologist."


All three of the devices being used in Vienna are part of a joint initiative between the Department of Ophthalmology and Optometrics and its international AI partners. The IDX-DR system that it uses was developed at the University of Iowa in the U.S. by a spin-off company and is the only approved, and therefore reliable, complete system in the world.


"With two million pixels or data points, it takes an extremely sharp image of the retina and the data are digitally transferred," explains Andreas Pollreisz, a retinal expert at MedUni Vienna. Based on the fundus photograph, the algorithm identifies anatomically relevant structures such as the macula, optic nerve and blood vessels and finally examines the entire image for pathological diabetic changes. Characteristic features of diabetes are micro-aneurysms, i.e. tiny bulges on fine blood vessels; bleeds within the retinal layers; hard exudates, i.e. fatty deposits in the retina; or even retinal angiogenesis, which is a sign of diabetic retinopathy that is already at an advanced stage.


The IDx-DR system automatically determines the image quality within minutes, as well as the presence of any diabetic retinal changes. Around 5 per cent of patients are found to have damage that is already significant, even though they do not have any symptoms. In the case of moderate findings (approximately 15 per cent of asymptomatic diabetics), constant monitoring is necessary—and this is also determined by the robot.


No longer detectable to the naked eye


International studies have shown that Artificial Intelligence, with its precise algorithms, can diagnose more quickly and accurately than a consultant. Says Schmidt-Erfurth: "AI can analyze things that an expert cannot detect with the naked eye." Nevertheless, there is a doctor at the end of the diagnostic chain: only a doctor can determine from the image what treatment is subsequently needed and perform the operation—on an individual basis in the spirit of precision medicine. At the same time, all positive results, and those that were inconclusive—for example, because of obstructing cataracts—are scientifically checked in MedUni Vienna's Vienna Reading Center.


"In cases of doubt, the robot will opt for a false-positive result, so that the patient goes to the ophthalmologist and is assured of receiving a reliable diagnosis. From among the first 450 patients that were screened by IDx-DR, we only identified a single case where a doctor could have given a more accurate diagnosis than the computer. In the other 449 cases, IDx-DR was correct or meticulous in its diagnosis" explains Bianca Gerendas. "This new technique not only relieves the burden on doctors during the initial steps but, above all, ensures that thousands of diabetics no longer go untreated," stresses Schmidt-Erfurth. "Because, when it comes to retinal damage, early detection is crucial."


IDx-DR is one of the first examples of Artificial Intelligence being used to support doctors in their everyday work. However, there are risks involved in every use of AI. A computer can only diagnose what it has been programmed to recognize: if it has been trained to diagnose diabetic retinopathy, it will not recognize a detached retina or age-related macular degeneration. "For this reason, it is important that such devices are strictly only used for their approved purpose, in precisely the same way as drugs." At the same time, Clinical Director Schmidt-Erfurth also warns against dubious screening services offered on the Internet or as apps. "The IDX-DR system is the only one of its kind in the world that has been approved and validated by large-scale studies. Only such complete systems can offer diagnostic reliability."

Tags:    

Disclaimer: This site is primarily intended for healthcare professionals. Any content/information on this website does not replace the advice of medical and/or health professionals and should not be construed as medical/diagnostic advice/endorsement or prescription. Use of this site is subject to our terms of use, privacy policy, advertisement policy. © 2020 Minerva Medical Treatment Pvt Ltd